Building Code-Related Design Criteria
For Virginia Tech's Blacksburg campus:
Ground Snow Load
30 psf
Wind Exposure
Category B (unless otherwise determined by actual site conditions)
Seismic Zone
2
Spectral Response Acceleration
- Ss%g: 28% (unless otherwise determined by actual site conditions)
- S1%g: 7% (unless otherwise determined by actual site conditions)
Subject to Damage from
- Weathering: Severe
- Frost Depth: 24” min.
- Termite: Moderate to heavy
- Decay: Slight to Moderate
Ice Shield Required
Yes
Flood Hazard
Some areas yes; refer to Flood Insurance Rate Maps (FIRM) for more information
Climate Zone
4
Winter Design Temperature
16 F
Yearly Heating Days
4150
Yearly Cooling Days
1154
Mean Annual temperature
55 F
Air Freezing Index
250
Latitude/Longitude
37° 13’ 38.94” N / 80° 25’ 19.70” W
For additional information, contact the Office of the University Building Official at 540-231-5534.
Contact the Office of the University Building Official
Chris Kiel
University Building Official
ckiel@vt.edu
540-231-4678
David S. Brown
Building Code Plan Reviewer/Inspector
davidsb22@vt.edu
540-204-5250
John Bush
Architect
bushj@vt.edu
540-598-0392
Marie Castillo
Assistant Permit Technician
mdotson@vt.edu
540-231-2414
Christopher McGrath
Building Code Plan Reviewer/Inspector
cmcgrath@vt.edu
540-835-4821
Gerald Smith
Assistant Permit Technician
geraldws@vt.edu
540-774-6724
Steve Smith
Building Code Plan Reviewer/Inspector
stsmith1@vt.edu
540-553-1929
Heather Snidow
Permit Technician/Administrative Coordinator
hsnidow@vt.edu
540-231-5534
Jack Thompson, Jr.
Building Code Plan Reviewer/Inspector
jlthomps@vt.edu
540-739-0129